D120SeriesDTUUserManual
ELinsTechnologyCo.,Limited
AT+DATAMODE=1
AT+SOCKETOPEN=1,UDP//switchtoSocketmode
AT+DATAOPEN
……
……
……//communication
……
……
+++//Switchtotheconfigurationmodel,thiscommandcan’tbedisplayed
AT+SOCKETCLOSE
4.2 TCP Mode
4.2.1 TCPclientTransparenttransferModealwaysonline
AT+GPRSCONFIG=1,cmnet,”wap”,”wap”
AT+CLIENTCONFIG=1,”210.105.96.117”,7777 //settheServerIPandport
AT+IDLETIME=0//alwaysonline
AT+REGINFO=0//closetheRegistrationinformationpacket
AT+KEEPALIVE=40,alivepacket//setthekeepalivepacket,(insecond)
AT+DTUID=12345678901 //settheDTUIDin11figures
AT+DATAMODE=1
AT+SOCKETOPEN=1,TCP //switchtoSocketmode
AT+DATAOPEN
……
……
……//communication
……
……
+++//Switchtothe
configurationmodel,thiscommandcan’tbedisplayed
AT+SOCKETCLOSE
4.2.2 TCPclientTransparenttransferModetransitorylink.
AT+GPRSCONFIG=1,cmnet,”wap”,”wap”
AT+CLIENTCONFIG=1,”210.105.96.117”,7777 //settheServerIPandport
AT+IDLETIME=5//thetimeoflastdata(inminute)
AT+REGINFO=2,1,”reginfo
//starttheRegistrationinformationpacket
AT+KEEPALIVE=40,alivepacket//setthekeepalivepacket,(insecond)
AT+DTUID=12345678901 //settheDTUIDin11figures